Digital Mammography: IWDM 2002 — 6th International Workshop on Digital MammographyHeinz-Otto Peitgen Springer Science & Business Media, 06.12.2012 - 596 Seiten This book contains the proceedings of the Sixth International Workshop on Digital Mammography held in Bremen, Germany, June 22-25, 2002. The Workshop was a forum for discussing new developments in digital mammography and its applications and included presentations by 135 experts from all over the world. It covers the latest developments in: Imaging Systems and Detectors, Image Quality, Image Processing and Display, Computer Aided Diagnosis, Soft Copy Reading, Clinical Studies of Digital Mammography or Related Modalities, 3D Techniques, Other Applications of Digital Mammography. |
Inhalt
3 | |
16 | |
A High Resolution 25 µm Hybrid SeleniumCCD Slot Scan Detector | 33 |
Simultaneous Acquisition of Diffraction Scattering and PhaseContrast | 48 |
Full Field Digital Mammography with a CCD Based SlotScanned | 51 |
Finding CLS Using a Multiresolution Oriented Local Energy Feature | 64 |
Image Quality 79 | 78 |
Effect of Detector Noise on Phantom Image Quality in a Number | 95 |
Comparison of BIRADS Lesion Descriptors and ComputerExtracted | 317 |
CAD Methodology Transfer from 2D to 3D Digital Mammography | 331 |
Temporal Mass Detection | 347 |
The use of Joint TwoView Information for Improving Computerized | 358 |
Incorporating Explanations into a CAD Tool for the Classification | 372 |
Experience with ComputerAided Detection in a LowVolume | 387 |
Optimal Texture Feature Extraction in Digital Mammograms | 402 |
Improved Computerized Detection of Individual Microcalcifications | 411 |
Features Analysis Comparison of ChargeCoupled Device CCD | 100 |
Digital Luminescence Mammography CR Without Magnification | 114 |
Automated Method for Measuring ContrasttoNoiseRatio CNR | 128 |
Dance DR Hunt RA Sajewicz A Huda W Ogden KM Sandborg | 141 |
Comparison of Objective and Subjective Methods to Assess Imaging | 142 |
Computer Aided Diagnosis 247 | 148 |
Image Quality of a Dual Side Reading Fuji Computed Mammography | 155 |
FilmScreen Artefact Detection in Mammograms | 174 |
Peripheral Thickness Correction for Volumetric Breast Density Estimation | 187 |
Analysis and Classification of Breast Masses by FuzzySetBased | 195 |
Enhanced Identification of Different Types of Microcalcifcations Using | 210 |
EM Texture Segmentation of Mammographic Images | 223 |
Representing Clustered Microcalcifications by their Cluster Shape | 237 |
Evaluation of Breast Ductal Networks Using Ramification Matrices | 249 |
Detection of Cases Occult at Screening | 262 |
Impact of computerplaced prompts on sensitivity and specificity with | 276 |
Improved Mammographic Accuracy with CAD Assisted Classification | 292 |
An Adaptive Similarity Measure for Automated Identification of Breast | 304 |
On The Problem of Bilateral Comparison of Mammograms | 428 |
MammoTrainer Computerbased Training for SoftCopy Reading | 441 |
Performance Evaluation of a Digital Reading Station for Screening | 455 |
Using Observer Models to Predict Softcopy Performance with Digital | 463 |
An Evaluation of a Commercial Prompting System in a Busy Screening | 471 |
Intraindividual Comparison of FullFieldDigitalMammography | 481 |
Is High Resolution Digital Luminescence | 491 |
Comparison of Full Field Digital and Analog Mammograms | 497 |
Average Glandular Dose with FullField Digital Mammography | 502 |
Preference Study of Reconstructed Image Quality in Mammographic | 517 |
Assessment Tools for Breast Surgery Based on 3D Surface Anatomy | 530 |
Comparing two Breast Density Metrics for Risk Assessment | 544 |
Subjective and ComputerBased Characterisation of Mammographic | 552 |
Application of DualEnergy Techniques to Digital Mammography | 566 |
Development of a ComputerAided Sketch System for Mammograms | 581 |
590 | |
Andere Ausgaben - Alle anzeigen
Digital Mammography: IWDM 2002 — 6th International Workshop on Digital ... Heinz-Otto Peitgen Keine Leseprobe verfügbar - 2011 |
Häufige Begriffe und Wortgruppen
Abstract algorithm analysis assessment automated automatic average benign BI-RADS breast cancer breast density Breast Imaging breast thickness breast tissue CAD system calcifications calculated classification clinical compared compressed breast computer-aided computer-aided detection computer-aided diagnosis contour contrast corresponding curve database detection detector developed diagnosis digital image digital mammograms digital mammography display energy enhancement estimate evaluated exposure false positive FFDM Figure film filter Fuji full-field digital mammography function glandular dose IEEE image processing image quality improve Karssemeijer lesion linear malignant mammographic images masses measured Medical Imaging microcalcifications monitor normal observer obtained optimal parameters parenchyma patterns performance phantom pixel PMMA radiographers radiologists Radiology readers registration resolution ROC curve score screen-film screening mammography segmentation methods sensitivity shot noise simulated softcopy spatial structures technique threshold tomosynthesis tumors vector visual wavelet x-ray